{"id":97335,"date":"2021-02-15T05:20:59","date_gmt":"2021-02-15T03:20:59","guid":{"rendered":"https:\/\/gahzly.com\/%d8%a3%d9%86%d9%88%d8%a7%d8%b9-%d8%a7%d9%84%d9%82%d9%88%d8%a7%d8%b7%d8%b9-%d8%a7%d9%84%d9%83%d9%87%d8%b1%d8%a8%d8%a7%d8%a6%d9%8a%d8%a9\/"},"modified":"2023-12-09T18:59:07","modified_gmt":"2023-12-09T16:59:07","slug":"4-types-of-electrical-circuit-breakers","status":"publish","type":"post","link":"https:\/\/gahzly.com\/en\/\u0645\u0642\u0627\u0644\/4-types-of-electrical-circuit-breakers\/","title":{"rendered":"4 Types of electrical circuit breakers"},"content":{"rendered":"<h1 style=\"text-align: center\"><strong><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">4 Types of electrical circuit breakers<\/span><\/span><\/strong><\/h1>\n<div class=\"kvgmc6g5 cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<p><a href=\"http:\/\/www.gahzly.com\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-32687 size-full\" src=\"https:\/\/www.gahzly.com\/wp-content\/uploads\/2021\/02\/4-\u0623\u0646\u0648\u0627\u0639-\u0627\u0644\u0642\u0648\u0627\u0637\u0639-\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.jpg\" alt=\"Types of electrical circuit breakers\" width=\"1151\" height=\"348\" title=\"l\" srcset=\"https:\/\/gahzly.com\/wp-content\/uploads\/2021\/02\/4-\u0623\u0646\u0648\u0627\u0639-\u0627\u0644\u0642\u0648\u0627\u0637\u0639-\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629.jpg 1151w, https:\/\/gahzly.com\/wp-content\/uploads\/2021\/02\/4-\u0623\u0646\u0648\u0627\u0639-\u0627\u0644\u0642\u0648\u0627\u0637\u0639-\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629-600x181.jpg 600w, https:\/\/gahzly.com\/wp-content\/uploads\/2021\/02\/4-\u0623\u0646\u0648\u0627\u0639-\u0627\u0644\u0642\u0648\u0627\u0637\u0639-\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629-1024x310.jpg 1024w, https:\/\/gahzly.com\/wp-content\/uploads\/2021\/02\/4-\u0623\u0646\u0648\u0627\u0639-\u0627\u0644\u0642\u0648\u0627\u0637\u0639-\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629-768x232.jpg 768w, https:\/\/gahzly.com\/wp-content\/uploads\/2021\/02\/4-\u0623\u0646\u0648\u0627\u0639-\u0627\u0644\u0642\u0648\u0627\u0637\u0639-\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629-640x194.jpg 640w, https:\/\/gahzly.com\/wp-content\/uploads\/2021\/02\/4-\u0623\u0646\u0648\u0627\u0639-\u0627\u0644\u0642\u0648\u0627\u0637\u0639-\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629-400x121.jpg 400w\" sizes=\"auto, (max-width: 1151px) 100vw, 1151px\" \/><\/a><\/p>\n<h2 dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">An overview of the types of electrical circuit breakers<\/span><\/span><\/h2>\n<h3 style=\"text-align: right\"><strong><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Types of electrical circuit breakers<\/span><\/span><\/strong><\/h3>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Electrical breakers are divided according to the method used to extinguish the spark inside them, which is as follows:<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Breakers are very oily<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">&#8221; The spark inside is extinguished using a large amount of oil &#8211; and the oil tank is connected to the ground, and the oil acts as an insulator between the poles of the breaker and each other and between the poles and the tank. &#8220;<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- The breakers are low in oil<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">&#8221; The spark is extinguished using a small amount of oil &#8211; the spark chamber in these breakers is isolated from the ground using stabilizing insulators. &#8220;<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- Compressed air circuit breakers<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">&#8221; The spark is extinguished by compressed air in its tanks.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">4- Breakers with self-pressure air<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">&#8221; The spark is extinguished by air compressed by a piston during the opening movement of the cutter.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">5- Sulfur hexafluoride breakers<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It uses compressed sulfur hexafluoride gas (SF6) as an extinguishing medium for the spark resulting from the separation.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">6- Vacuum partitions<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">A vacuum medium is used between the contact points to prevent sparks from occurring between them.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Breakers used in medium voltage distribution panels<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">A- Oily incisors &#8211; a lot of oil<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">As used in Czech-made distribution boards<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">B &#8211; Oil cutters &#8211; low oil<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">As used in the Yugoslav Radaknacher type distribution panels &#8211; Energo Invest<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Russian-made distribution panels and Igmac distribution panels. Siemens &#8220;<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Polish and Italian paintings.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">C- Vacuum partitions:<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">As used in IMAC distribution panels &#8221; Siemens &#8221; And the paintings are Arab style<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">D- Circuit breakers charged with sulfur hexafluoride gas (SF6).<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">As used in Arab distribution panels. A.B.B&#8221;<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">First: Oil circuit breakers. A lot of oil &#8221; Bulk \u2013 Oil &#8220;C.B&#8221;&#8221;<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The high oil cutter is composed of the following parts: as shown in (1) &#8221; Tank 1&#8243; &#8211; Top cover 8 &#8211; Penetration insulators 9 &#8211; Mechanical parts 16 &#8211; 21 Contact points 14-15.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">In the high-oil switch used at medium voltage of 11.6 kV, one tank is used for the three phases &#8211; and the tank is of a thickness proportional to the mechanical stresses &#8211; and the tank and the upper cover are connected to the ground &#8211; and the tank is insulated from the inside with a material that prevents the spark from reaching the body of the tank from the inside &#8211; and it is provided The tank has an oil indicator to determine the oil level inside the tank &#8220;3&#8221; The tank has an upper opening for filling oil and a lower opening for emptying oil.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Form &#8220;1&#8221; The cutter shows a lot of oil &#8211; and it is cut in one of the three faces during the opening process (the moment of cutting). In the figure we find that the fixed contact point is &#8220;14&#8221; At the end of the penetration insulator &#8220;9&#8221; The moving contact point is &#8220;15&#8221; Mounted on an arm made of \u201c16\u201d bakelite insulating material. This arm moves vertically by rotating the \u201c21\u201d part. \u2013 The switch is connected by rotating part \u201c21\u201d With an external lever &#8211; the rotating movement turns into a straight, vertical movement that attracts the moving contact points upward to connect to the fixed point. The switch has a special part that keeps the cutter in the connected position.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The separation is done manually or with an electrical separation file by attracting the part that maintains the connection position, so the moving contact points become free to move and fall under the influence of their weight away from the fixed points to complete the separation.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a7 When the breaker is opened while the current is passing, a high-temperature spark is formed that leads to the evaporation of a small portion of the oil. This evaporation leads to the formation of gases (70% of which are hydrogen). Hydrogen has the property of rapidly cooling the spark, which leads to its extinguishing. After extinguishing the spark, the gases exit to the upper part of the spark. The key is that it can mix with oxygen to form flammable gases, so the hydrogen must come out cold to the surface.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a7 These breakers are vulnerable to increased pressure, so the tank mounting bolt \u201c7\u201d is installed Sideways to allow the tank to be separated from the upper part during increased pressure<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a7 An internal spark may occur between the faces and each other or between them and the tank when there is increased humidity in the oil or increased pollution.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Therefore, the following must be followed when operating oily switches<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Ensure that the oil level in the cutter matches the mark on the oil level indicator.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- Cleanliness of the ventilation hole.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- The external contact points with the distribution bars in the cell must be strong and smooth to achieve good contact.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">4- The fixed and moving internal contact point must be strong to achieve good contact, knowing that the lack of strong contact inside or outside the oil tank leads to an increase in the temperature of the contact point and thus leads to an increase in the temperature of the oil with the passage of high currents that may lead to the oil igniting during separation. With the palace.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">5- Ensure that the oil is safe and conforms to technical specifications.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Second: The breakers are low in oil<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Low-oil circuit breakers are designed to have the following properties:<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Oil is used to extinguish the spark only, and the amount of oil is small but sufficient to extinguish the spark<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- The tank is designed to withstand high mechanical stresses and is therefore safe against explosions<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">And ignition if proper operating methods are followed<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- The body of the cutter is connected to the constant voltage Live-Tank<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">4- The cutter\u2019s body is isolated from the ground with mounting insulators, which are made of Persulene.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Abox &#8221; Figure 2 &#8220;<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Installation:<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Figure \u201c2\u201d shows Installing one of the low-oil breakers &#8221; Russian type &#8221; It is used in medium voltage networks and consists of three current units for three phases, and each unit is installed in the circuit breaker \u201cFigure 3\u201d. Of moisture-absorption-resistant insulating tube \u201c6\u201d &#8211; It is connected on both sides by metal parts (the upper part \u201c7\u201d and the lower part \u201c3\u201d)<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">In the upper part:-<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">From the cutter there is a moving contact point &#8220;8&#8221; And the mechanical parts for separation and connection &#8211; the upper part has the \u201c11\u201d entry hole. And the ventilation hole is \u201c12\u201d<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">And in the lower part:-<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">From the cutter there is a fixed contact point &#8220;2&#8221; And the spark extinguishing chamber \u201c4\u201d And oil level indication &#8220;5&#8221; It is noted that the oil level must cover the spark chamber, and there is a hole in this part to extract the oil \u201c13\u201d. When the switch is disconnected, a spark is generated between the two contact points inside the chamber &#8211; the spark chamber cuts the spark &#8211; and the oil extinguishes it.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<h4 dir=\"auto\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-54453\" src=\"https:\/\/gahzly.com\/wp-content\/uploads\/2022\/03\/closeup-electrical-panel-with-circuit-breakers-apartment-jpg.webp\" alt=\"\" width=\"670\" height=\"447\" title=\"l\" srcset=\"https:\/\/gahzly.com\/wp-content\/uploads\/2022\/03\/closeup-electrical-panel-with-circuit-breakers-apartment-jpg.webp 670w, https:\/\/gahzly.com\/wp-content\/uploads\/2022\/03\/closeup-electrical-panel-with-circuit-breakers-apartment-jpg-600x400.webp 600w, https:\/\/gahzly.com\/wp-content\/uploads\/2022\/03\/closeup-electrical-panel-with-circuit-breakers-apartment-640x427.jpg 640w, https:\/\/gahzly.com\/wp-content\/uploads\/2022\/03\/closeup-electrical-panel-with-circuit-breakers-apartment-400x267.jpg 400w\" sizes=\"auto, (max-width: 670px) 100vw, 670px\" \/><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">[]<\/span><\/span><strong><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Components of electrical circuit breakers<\/span><\/span><\/strong><\/h4>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Bottom cover<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- Fixed contact points<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- The lower part of the body<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">4- Spark room<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">5- Oil level indication<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">6- A cylinder of insulating material to absorb moisture<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">7- The upper part<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">8- Moving contact points<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">9- Cylinder to facilitate movement<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">10- Oil return sump<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">11- Oil entry hole<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">12- Ventilation hole<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">13- Oil leakage<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<h4 dir=\"auto\"><strong><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Precautions to be followed when operating low-oil switches:<\/span><\/span><\/strong><\/h4>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Change the oil every 3 times due to a short circuit in the network.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- Take care not to reconnect after disconnecting the breaker during the short peak hour.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- Take care not to perform disconnection and connection maneuvers on normal loads during peak hours.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">4- Be careful not to reconnect it immediately after disconnecting the switch &#8211; but it must be reconnected after that<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Sufficient time for the oil to return to its normal temperature.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">5- Check the oil level in the switches.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">6- Ensure that there is no oil leakage.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">7- Follow regular maintenance procedures.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">8- Set class times to the stipulated times<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<h4 dir=\"auto\"><strong><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Therefore, the following must be adhered to:<\/span><\/span><\/strong><\/h4>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1. Numbering the keys in the station for ease of following, operating and monitoring the keys.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2. Make a record to track the number of times of short-term and regular dismissal.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3. Creating prevention records to record device control and tests.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<h4 dir=\"auto\"><strong><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Disadvantages of using electrical oil as a medium to extinguish the spark:<\/span><\/span><\/strong><\/h4>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- The lifespan of the contact bits in the switches is short and requires frequent and frequent maintenance<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- The possibility of popping is high because the gaseous products from the oil analysis after extinguishing the spark are formed<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Flammable<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- Arc recoil tendency<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">4- Uneconomical use in industrial loads that need to be disconnected and restarted<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Frequent delivery.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">5- The duration of the electric arc at low currents is large.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">6- Humidity and dust reduce the intensity of electrical isolation<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">For these reasons, research turned to the necessity of using another medium to extinguish the spark &#8211; sulfur hexafluoride gas, SF6, which has excellent and multiple properties that help eliminate all of these aforementioned defects in the use of electrical oil in electrical breakers, as well as the use of vacuum breakers.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<h4 dir=\"auto\"><strong><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Third, vacuum circuit breakers:<\/span><\/span><\/strong><\/h4>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Operating theory<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The theory of operation of these breakers depends on the absence of a spark during separation of the connection points inside a vacuum medium &#8211; and the vacuum medium has a high quality of insulation in relation to air insulation, and this property helps to reduce the distance between the separation points to millimeters, which helped reduce the separation time for the breakers. .<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Installation<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">&#8220;Figure 4&#8221; It shows the installation of the breaker used in the EGIMAC 11 KV distribution panels. We find that the breaker unit is composed of:<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">A vacuum metal spark chamber containing fixed and moving contact points connected to the mechanical parts for separation and connection &#8211; and the upper points are the fixed points.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Penetrating insulators for fixed and moving points are installed above and below the spark chamber to prevent an electric arc from occurring outside the spark chamber.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Precautions to be followed when operating:<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Do not expose the cutter to any mechanical shocks that may lead to a breakage of the cutter.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- Clean the upper and lower penetration insulators of the cutter from dust and moisture.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- Recording short disconnection times and the normal load for each circuit breaker.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<h4 dir=\"auto\"><strong><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Fourth: Circuit breakers charged with sulfur hexafluoride gas<\/span><\/span><\/strong><\/h4>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Sulfur hexafluoride gas is used as a medium to extinguish a spark or an electric arc, and it is used as an insulating medium due to the following properties:<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1 &#8211; It has an ability equal to 2.5 insulating strengths of air at atmospheric pressure, and the insulating strength can be increased to 10<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Air isolation times increase in pressure<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- A density higher than that of air<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- It has the ability to absorb electrons, which cause sparks, and turns into fluoride hexa gas<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Sulfur.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">4- It has a high cooling capacity that helps extinguish the spark<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The cutter charged with sulfur hexafluoride gas is used in 11 KV Arab distribution panels. Breakers of this type are similar in structure to low-oil breakers in that there are moving contact points and fixed contact points &#8211; but these points move in a medium charged with sulfur hexafluoride gas.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is connected to the charged tank and is shown to indicate the gas pressure level inside the cutter.<\/span><\/span><\/div>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<h3 dir=\"auto\"><strong><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">When operating these circuit breakers, the following must be taken into account:<\/span><\/span><\/strong><\/h3>\n<\/div>\n<div class=\"o9v6fnle cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">1 &#8211; Monitor the gas pressure inside the spark chamber and record it during the shift<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- Take care not to use force and expose the keys to mechanical shocks that may lead to their breakage and gas leakage<\/span><\/span><\/div>\n<div dir=\"auto\" style=\"text-align: right\">\n<p>&nbsp;<\/p>\n<p><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">To view the home page for electrical circuit breakers, click<\/span><\/span><a href=\"\/?product_cat=\u0642\u0648\u0627\u0637\u0639-\u0648-\u0623\u062c\u0647\u0632\u0629-\u062a\u062d\u0643\u0645\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">here<\/span><\/span><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">To know our latest products and special offers, please subscribe to our social media pages:<\/span><\/span><\/p>\n<p><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">Our Facebook page=&gt; <\/span><\/span><a href=\"https:\/\/www.facebook.com\/Gahzlystore\/\" target=\"_blank\" rel=\"noopener\"><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">Gahzlystore<\/span><\/span><\/a><\/p>\n<p><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Our Twitter page=&gt; <\/span><\/span><a href=\"https:\/\/twitter.com\/gahzly1\" target=\"_blank\" rel=\"noopener\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Gahzlystore<\/span><\/span><\/a><\/p>\n<\/div>\n<div dir=\"auto\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>4 Types of electrical circuit breakers An overview of the types of electrical circuit breakers Types of electrical circuit breakers Electrical breakers are divided according to the method used to extinguish the spark inside them, which is as follows: 1- Breakers are very oily &#8221; The spark inside is extinguished using a large amount of [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":54220,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7428,12318],"tags":[7785,7783,7782,8172,14097,14098],"class_list":["post-97335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-circuit-breakers-and-control-devices","category-sell-online","tag-breakers-en","tag-devices","tag-electric","tag-electrical-en","tag--en"],"featured_image_src":{"landsacpe":["https:\/\/gahzly.com\/wp-content\/uploads\/2022\/02\/how-do-circuit-breakers-work-1037x445.png",1037,445,true],"list":["https:\/\/gahzly.com\/wp-content\/uploads\/2022\/02\/how-do-circuit-breakers-work-463x348.png",463,348,true],"medium":["https:\/\/gahzly.com\/wp-content\/uploads\/2022\/02\/how-do-circuit-breakers-work-300x225.png",300,225,true],"full":["https:\/\/gahzly.com\/wp-content\/uploads\/2022\/02\/how-do-circuit-breakers-work.png",1037,778,false]},"jetpack_featured_media_url":"https:\/\/gahzly.com\/wp-content\/uploads\/2022\/02\/how-do-circuit-breakers-work.png","_links":{"self":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/posts\/97335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/comments?post=97335"}],"version-history":[{"count":0,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/posts\/97335\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media\/54220"}],"wp:attachment":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media?parent=97335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/categories?post=97335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/tags?post=97335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}