{"id":98000,"date":"2022-01-17T02:32:51","date_gmt":"2022-01-17T00:32:51","guid":{"rendered":"https:\/\/gahzly.com\/%d8%a7%d9%84%d9%83%d9%88%d9%86%d8%aa%d8%a7%d9%83%d8%aa%d9%88%d8%b1-%d9%88-%d8%b7%d8%b1%d9%8a%d9%82%d9%87-%d8%aa%d8%ba%d9%8a%d9%8a%d8%b1-%d8%a7%d9%84%d9%83%d9%88%d9%8a%d9%84\/"},"modified":"2023-12-25T15:25:48","modified_gmt":"2023-12-25T13:25:48","slug":"contactor-and-how-to-change-the-coil","status":"publish","type":"post","link":"https:\/\/gahzly.com\/en\/\u0645\u0642\u0627\u0644\/contactor-and-how-to-change-the-coil\/","title":{"rendered":"Contactor and how to change the coil 220\/110\/24"},"content":{"rendered":"<div class=\"kvgmc6g5 cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<div dir=\"auto\">\n<div class=\"kvgmc6g5 cxmmr5t8 oygrvhab hcukyx3x c1et5uql ii04i59q\">\n<h1 dir=\"auto\" style=\"text-align: center\"><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">Contactor and how to change the coil<\/span><\/span><\/h1>\n<h2 style=\"text-align: right\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-52306 size-full\" src=\"https:\/\/gahzly.com\/wp-content\/uploads\/2022\/01\/-\u0648-\u0637\u0631\u064a\u0642\u0647-\u062a\u063a\u064a\u064a\u0631-\u0627\u0644\u0643\u0648\u064a\u0644-1-jpg.webp\" alt=\"Contactor and how to change the coil\" width=\"225\" height=\"225\" title=\"l\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Contactor and how to change the coil<\/span><\/span><\/h2>\n<h2><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Contactor:<\/span><\/span><\/h2>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is an electro-mechanical connection and disconnection device<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is controlled by a coil whose terminals are on the contactor (A1, A2).<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">When current passes through this coil, the contactor closes the main contacts.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">He changes the position of the control contacts, so that the closed contacts become open and the open contacts become closed.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">With the main contacts closed, the electrical circuit is completed between the supply and the load.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The following figure shows the shape of the contactor.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The following figure shows the contactor symbol in electrical diagrams.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The most important information written on the contactor is:<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Coil Voltage.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- Electrode voltage (main contacts)&#8230;<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- Current or power of the poles.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">4- Operating Clique.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<h3 dir=\"auto\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-52304\" src=\"https:\/\/www.gahzly.com\/wp-content\/uploads\/2022\/01\/-\u0648-\u0637\u0631\u064a\u0642\u0647-\u062a\u063a\u064a\u064a\u0631-\u0627\u0644\u0643\u0648\u064a\u0644-e1642369353901.jpg\" alt=\"\" width=\"600\" height=\"240\" title=\"l\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0Contactor parts:<\/span><\/span><\/h3>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Electromagnet: It consists of a coil and a magnetic core, and it either operates on direct current<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">(6,12,24,48,60,80), or works on alternating current (24,50,110,220,380).<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- Poles (main contacts): inputs (L1, L2, L3), outputs (T1, T2, T3).<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- Auxiliary contacts: They are either open contacts (N.O.), or closed contacts (N.C) with a time delay that open and close after a period of time is placed.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<h3 dir=\"auto\" style=\"text-align: right\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0Operation code:<\/span><\/span><\/h3>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\" style=\"text-align: right\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">AC1: For ohmic circuits (P.F=1) such as heating and lighting operations, i.e. we do not have XL or XC.<\/span><\/span><\/div>\n<div dir=\"auto\" style=\"text-align: right\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">AC2: Related to wound circuit motors.<\/span><\/span><\/div>\n<div dir=\"auto\" style=\"text-align: right\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">AC&#8217;2: Related to wound-circuit motors.<\/span><\/span><\/div>\n<div dir=\"auto\" style=\"text-align: right\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">AC3: Related to squirrel cage motors.<\/span><\/span><\/div>\n<div dir=\"auto\" style=\"text-align: right\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">AC4: Designed for frequent disconnection and connection within a short time.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The contactor is available with a power scale (KW) with the following standard values:<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\" style=\"text-align: right\">( 4, 5.5, 7.5, 11, 15, 22, 30, 37, 45, 55, 75, 110 )<\/div>\n<div dir=\"auto\"><\/div>\n<h3 dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0How to know and determine the edges of the contactor?!<\/span><\/span><\/h3>\n<div dir=\"auto\"><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Before connecting to the contactor, you must first determine the main contact points, the closed and open auxiliary contact points, as well as the two ends of the coil.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">For main contacts, three points are usually in the open position<\/span><\/span><\/div>\n<div dir=\"auto\" style=\"text-align: right\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">(normally open) and take the numbers 1,3,5 as the input (as these inputs to the contactor are the outputs of the electrical circuit breaker) and 2,4,6 as the output.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0As for auxiliary contacts, there are some that are in a normal open position<\/span><\/span><\/div>\n<div dir=\"auto\" style=\"text-align: right\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">(normally open) and abbreviated with the letters (N.O), and some of them are in a normally closed position (normally closed) and abbreviated with the letters (N.C)<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">As for the numbers, the open auxiliary points take the numbers (14-13) or the following numbers that start with the number 3, such as (23-24), (33-34)&#8230; and so on..<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The closed auxiliary points take the numbers (11-12) or the following numbers that start with the number 1, such as (21-22), (31-32)&#8230; and so on..<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is possible to determine whether the point is open or closed using a series lamp or multimeter<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Where any contact point outside the circuit is tested, that is, the parties connected to it are separated.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">If the multimeter pointer does not move on Analog devices or the letter OL appears on Digital devices,<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Press the manual button to make the contactor, the indicator will move or give 00. This means that these points are open in the normal position (N.O).<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">When the hand is removed from the button, the contacts will return to their normal position, and vice versa in the case of closed points (N.C), where the multimeter pointer will move or give 00.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">When you press the contactor button, the state will change, and when you remove the hand from it, the contacts will return to their normal position.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<hr \/>\n<h4 dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0comments :<\/span><\/span><\/h4>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- Some contactors carry a certain number of auxiliary contact points, and no other points can be added.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">As it is found in many brands, the contactor has one auxiliary contact point and a piece can be installed on it that carries a number of additional auxiliary points.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It becomes an integral part of the contactor, moving by the force of the magnetic field of the same coil.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is possible for a single point or piece to contain two or more open and closed points.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- This same idea is used to place a mechanical timer on the contactor.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<h3 dir=\"auto\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-52302\" src=\"https:\/\/gahzly.com\/wp-content\/uploads\/2022\/01\/\u0627\u0644\u0643\u0648\u0646\u062a\u0627\u0643\u062a\u0648\u0631-\u0648-\u0637\u0631\u064a\u0642\u0647-\u062a\u063a\u064a\u064a\u0631-\u0627\u0644\u0643\u0648\u064a\u0644.gif\" alt=\"\" width=\"188\" height=\"188\" title=\"l\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0For the ends of the coil:<\/span><\/span><\/h3>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The coil usually has two terminals, designated A1-A2 or A-B. When measured with a multimeter, it will give a certain resistance value, not zero, and this is very important in maintenance.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Contactors have coils that operate at different voltage values, including 24, 48, 110, 220, and 380 volts. The higher the coil operates at a voltage, the greater its resistance value<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is wound with a thinner wire diameter and more turns. R=<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is possible for the same contactor to operate with a 24 volt or 380 volt coil, and the coil may be changed individually.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The contactor is left as it is, and therefore the value of the voltage at which the coil operates is written on it itself, and not on the body of the contactor, and the number appears on the outer surface of the contactor.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">There are many types and sizes of contactors,<\/span><\/span><\/div>\n<div dir=\"auto\">\n<hr \/>\n<\/div>\n<h3 dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">When buying or changing a contactor, you must know three basic things:<\/span><\/span><\/h3>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">1- The intensity of the current or capacity of the load that will operate through this contactor.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">2- The voltage at which the control circuit operates<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">3- Number of open and closed auxiliary contact points.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><\/div>\n<h3 dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0The intensity of the current or capacity of the load that will work with this contactor.<\/span><\/span><\/h3>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">You must first know that the part that bears the intensity of the motor current inside the contactor is the three main contacts<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">These points are responsible for delivering current to the motor<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Therefore, its size and the type of material from which it is manufactured must be able to withstand the current consumed by the load, whatever its type.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Whenever the value of the contactor current is greater than the value of the load current,<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It was better and gave the contactor a longer life, but economically, a suitable contactor should be chosen and not much higher.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">This depends on the type of load and the number of times it is connected and disconnected, and the brand of contactor must also be taken into consideration<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">If the number of stop and start times is more, a contactor with a higher value is needed.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The better the brand of contactor, you can choose it with a value close to the value of the load current.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is known that the same capacity of the motor, whenever it operates at a higher voltage, the intensity of its current decreases, and vice versa<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Therefore, you will find a table on the 9 amp contactor that records if the engine is running at 220 volts, so the contactor is suitable for an engine with a capacity of up to 3 HP.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">If the engine runs on 380 volts, the same contactor is suitable for an engine with a capacity of up to 5.5 HP.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><\/div>\n<h3 dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0The voltage at which the control circuit operates (coil voltage).<\/span><\/span><\/h3>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">It is related to the value of the voltage difference in the control circuit. It is not required that the control circuit operate at the same voltage as the source.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Rather, it is preferable for it to operate with a lower voltage difference and powered by an independent circuit breaker.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">The control circuit voltage is what will reach the contactor coil, therefore<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">If the control circuit is 24 volts, the voltage of the contactor coil must be 24 volts, regardless of the voltage of the source with which it will operate.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Engine: This is a very important point during the connection process.<\/span><\/span><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><\/div>\n<h3 dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">\u00a0Number of open and closed auxiliary contact points.<\/span><\/span><\/h3>\n<div dir=\"auto\"><\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Depending on what is required of the control circuit, it is possible for the circuit to be without any auxiliary points.<\/span><\/span><\/div>\n<div dir=\"auto\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Or it contains a certain number of open or closed points (that is, depending on the application to be performed through the electrical circuit).<\/span><\/span><\/div>\n<div dir=\"auto\">\n<hr \/>\n<\/div>\n<\/div>\n<div class=\"cxmmr5t8 oygrvhab hcukyx3x c1et5uql o9v6fnle ii04i59q\">\n<div dir=\"auto\">\n<h2><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Replace contactor coil<\/span><\/span><\/h2>\n<p><iframe loading=\"lazy\" title=\"How To Replace Contactor Coil #Short Video - AC&amp;R World\" width=\"1140\" height=\"641\" src=\"https:\/\/www.youtube.com\/embed\/YAfWkQ4f48c?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<hr \/>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-51595\" title=\"What is e-commerce? 1 What is e-commerce? 1\" src=\"https:\/\/www.gahzly.com\/wp-content\/uploads\/2019\/07\/%D9%83%D8%B4%D8%A7%D9%81-%D9%84%D8%A7%D9%86%D8%B2%D9%8A%D9%86%D9%8A-%D9%85%D9%8A%D8%AA%D8%A7%D9%84%D8%A7%D9%8A%D8%AA.gif\" alt=\"gif\" width=\"188\" height=\"188\" \/><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">Try\u00a0<\/span><\/span><a href=\"https:\/\/www.gahzly.com\/\"><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">Gahzly<\/span><\/span><\/a><span style=\"vertical-align: inherit\"><span class=\"\" style=\"vertical-align: inherit\">\u00a0for a fun shopping trip<\/span><\/span><\/p>\n<h4><span id=\"%D9%8A%D8%B3%D8%B9%D8%AF%D9%86%D8%A7_%D8%B2%D9%8A%D8%A7%D8%B1%D8%AA%D9%83%D9%85_%D8%B5%D9%81%D8%AD%D8%A7%D8%AA%D9%86%D8%A7_%D8%B9%D9%84%D9%89_%D9%85%D9%88%D8%A7%D9%82%D8%B9_%D8%A7%D9%84%D8%AA%D9%88%D8%A7%D8%B5%D9%84_%D8%A7%D9%84%D8%A7%D8%AC%D8%AA%D9%85%D8%A7%D8%B9%D9%8A_%D8%AD%D9%8A%D8%AB_%D9%86%D9%82%D9%88%D9%85_%D8%A8%D9%86%D8%B4%D8%B1_%D8%B9%D8%B1%D9%88%D8%B6_%D8%AD%D8%B5%D8%B1%D9%8A%D8%A9_%D8%B9%D9%84%D9%89_%D9%85%D9%88%D9%82%D8%B9%D9%86%D8%A7_%D8%A7%D9%84%D8%A7%D9%84%D9%83%D8%AA%D8%B1%D9%88%D9%86%D9%8A\" class=\"ez-toc-section\"><\/span><span id=\"%D9%8A%D8%B3%D8%B9%D8%AF%D9%86%D8%A7_%D8%B2%D9%8A%D8%A7%D8%B1%D8%AA%D9%83%D9%85_%D8%B5%D9%81%D8%AD%D8%A7%D8%AA%D9%86%D8%A7_%D8%B9%D9%84%D9%89_%D9%85%D9%88%D8%A7%D9%82%D8%B9_%D8%A7%D9%84%D8%AA%D9%88%D8%A7%D8%B5%D9%84_%D8%A7%D9%84%D8%A7%D8%AC%D8%AA%D9%85%D8%A7%D8%B9%D9%8A_%D8%AD%D9%8A%D8%AB_%D9%86%D9%82%D9%88%D9%85_%D8%A8%D9%86%D8%B4%D8%B1_%D8%B9%D8%B1%D9%88%D8%B6_%D8%AD%D8%B5%D8%B1%D9%8A%D8%A9_%D8%B9%D9%84%D9%89_%D9%85%D9%88%D9%82%D8%B9%D9%86%D8%A7_%D8%A7%D9%84%D8%A7%D9%84%D9%83%D8%AA%D8%B1%D9%88%D9%86%D9%8A\" class=\"ez-toc-section\"><\/span><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">We are pleased that you visit our social media pages, where we publish exclusive offers on our website.<\/span><\/span><\/h4>\n<p><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Our Facebook page\u00a0<\/span><\/span><a href=\"https:\/\/www.facebook.com\/Gahzlystore\/\" target=\"_blank\" rel=\"noopener\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Here<\/span><\/span><\/a><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">.<\/span><\/span><\/p>\n<p><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Our Twitter account\u00a0<\/span><\/span><a href=\"https:\/\/twitter.com\/gahzly1\" target=\"_blank\" rel=\"noopener\"><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">Here<\/span><\/span><\/a><span style=\"vertical-align: inherit\"><span style=\"vertical-align: inherit\">.<\/span><\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Contactor and how to change the coil Contactor and how to change the coil Contactor: It is an electro-mechanical connection and disconnection device It is controlled by a coil whose terminals are on the contactor (A1, A2). When current passes through this coil, the contactor closes the main contacts. He changes the position of the [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":52309,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7416,7375],"tags":[14264,7770,7782,14265,14266,14267,14268,8109],"class_list":["post-98000","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-accessories-en-2","category-articles","tag-220-110-24-en","tag-accessories-en","tag-electric","tag--en"],"featured_image_src":{"landsacpe":["https:\/\/gahzly.com\/wp-content\/uploads\/2022\/01\/\u0627\u0644\u0643\u0648\u0646\u062a\u0627\u0643\u062a\u0648\u0631-\u0648-\u0637\u0631\u064a\u0642\u0647-\u062a\u063a\u064a\u064a\u0631-\u0627\u0644\u0643\u0648\u064a\u0644-220-110-24-1140x445.jpg",1140,445,true],"list":["https:\/\/gahzly.com\/wp-content\/uploads\/2022\/01\/\u0627\u0644\u0643\u0648\u0646\u062a\u0627\u0643\u062a\u0648\u0631-\u0648-\u0637\u0631\u064a\u0642\u0647-\u062a\u063a\u064a\u064a\u0631-\u0627\u0644\u0643\u0648\u064a\u0644-220-110-24-463x348.jpg",463,348,true],"medium":["https:\/\/gahzly.com\/wp-content\/uploads\/2022\/01\/\u0627\u0644\u0643\u0648\u0646\u062a\u0627\u0643\u062a\u0648\u0631-\u0648-\u0637\u0631\u064a\u0642\u0647-\u062a\u063a\u064a\u064a\u0631-\u0627\u0644\u0643\u0648\u064a\u0644-220-110-24-300x169.jpg",300,169,true],"full":["https:\/\/gahzly.com\/wp-content\/uploads\/2022\/01\/-\u0648-\u0637\u0631\u064a\u0642\u0647-\u062a\u063a\u064a\u064a\u0631-\u0627\u0644\u0643\u0648\u064a\u0644-220-110-24-jpg.webp",1920,1080,false]},"jetpack_featured_media_url":"https:\/\/gahzly.com\/wp-content\/uploads\/2022\/01\/-\u0648-\u0637\u0631\u064a\u0642\u0647-\u062a\u063a\u064a\u064a\u0631-\u0627\u0644\u0643\u0648\u064a\u0644-220-110-24-jpg.webp","_links":{"self":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/posts\/98000","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/comments?post=98000"}],"version-history":[{"count":0,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/posts\/98000\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media\/52309"}],"wp:attachment":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media?parent=98000"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/categories?post=98000"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/tags?post=98000"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}