{"id":125639,"date":"2026-08-16T02:41:23","date_gmt":"2026-08-15T23:41:23","guid":{"rendered":"https:\/\/gahzly.com\/?post_type=product&#038;p=125639"},"modified":"2026-09-21T16:36:29","modified_gmt":"2026-09-21T13:36:29","slug":"%d9%85%d9%83%d8%ab%d9%81-%d8%aa%d8%ad%d8%b3%d9%8a%d9%86-%d9%85%d8%b9%d8%a7%d9%85%d9%84-%d8%a7%d9%84%d9%82%d8%af%d8%b1%d8%a9-440-%d9%81%d9%88%d9%84%d8%aa","status":"publish","type":"product","link":"https:\/\/gahzly.com\/en\/product\/%d9%85%d9%83%d8%ab%d9%81-%d8%aa%d8%ad%d8%b3%d9%8a%d9%86-%d9%85%d8%b9%d8%a7%d9%85%d9%84-%d8%a7%d9%84%d9%82%d8%af%d8%b1%d8%a9-440-%d9%81%d9%88%d9%84%d8%aa\/","title":{"rendered":"\u0645\u0643\u062b\u0641 \u062a\u062d\u0633\u064a\u0646 \u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629 440 \u0641\u0648\u0644\u062a"},"content":{"rendered":"<h2><strong>The comprehensive operational and engineering guide: Physical operating principle and reactive-power capability of the Himel capacitor (440 V)<\/strong><\/h2>\n<h3 style=\"font-family:&apos;Google Sans&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Structural analysis and safety components of the Himel power-factor correction capacitor<\/strong><\/b><\/h3>\n<ul style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<li style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Self-healing metallized film technology (Self-Healing Film):<\/strong><\/b><\/p>\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Allows continued capacitor operation by isolating microscopic internal electrical punctures without stopping operation or significantly reducing kvar capacity on site.<\/p>\n<\/li>\n<li style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Mechanical overpressure protection system (Overpressure Disconnector):<\/strong><\/b><\/p>\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Fully disconnects the electrical connection if the housing expands because of an internal fault, providing strong safety inside the distribution panel through Gahzly.<\/p>\n<\/li>\n<li style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Fast integrated discharge resistors (Built-in Discharge Resistors):<\/strong><\/b><\/p>\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Discharge the stored electrical energy after the capacitor is disconnected, protecting technicians and simplifying safe re-switching on site.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family:&apos;Google Sans&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Operational excellence and construction feasibility in supply projects (Himel 440V Capacitor)<\/strong><\/b><\/h3>\n<ul style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<li style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Helps eliminate utility power-factor penalties and achieve strong financial savings:<\/strong><\/b><\/p>\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Raises the power factor toward unity, reducing billing penalties and improving transformer utilization on site.<\/p>\n<\/li>\n<li style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Strong tolerance for harmonics and elevated voltage:<\/strong><\/b><\/p>\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">The 440 V design provides longer service life than conventional capacitors in demanding industrial environments through Gahzly.<\/p>\n<\/li>\n<li style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Compact aluminum body for easy installation and connection:<\/strong><\/b><\/p>\n<p style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Includes a lower mounting stud and robust heat-resistant terminals to ensure reliable electrical connection inside the panel on site.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family:&apos;Google Sans&apos;, sans-serif;line-height:1.15;margin-top:0px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Advanced technical specifications and consulting schedule&#x1f4ca;<\/strong><\/b><\/h3>\n<figure class=\"table\">\n<table style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-bottom:32px;margin-top:0px\">\n<thead style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<tr style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<th style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><strong style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-bottom:0px;margin-top:0px\">Technical and mechanical characteristic<\/strong><\/th>\n<th style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><strong style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-bottom:0px;margin-top:0px\">Approved standard product specification<\/strong><\/th>\n<th style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><strong style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-bottom:0px;margin-top:0px\">Practical impact in the site working environment<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<tr style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Brand and engineering approval<\/strong><\/span><\/b><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Himel<\/span><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Supports immediate acceptance in consultant specifications and site inspection records.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Capacitor construction technology<\/strong><\/span><\/b><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Self-healing dry-type capacitors (Dry Type)<\/span><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Complete environmental safety with no liquid-leakage or ignition risk inside the panel.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Rated and maximum operating voltage<\/strong><\/span><\/b><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">440 V three-phase (440V 3-Phase)<\/span><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Excellent tolerance for elevated voltage and harmonics generated by inverters through Gahzly.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Supported standard network frequency<\/strong><\/span><\/b><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Automatically compatible with 50 \/ 60 Hz<\/span><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Full compatibility with distribution networks and standby diesel generators on site.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Safety and self-protection systems<\/strong><\/span><\/b><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Overpressure disconnection + discharge resistors<\/span><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Protects the panel from explosion risk and improves technician safety during maintenance.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Outer housing material<\/strong><\/span><\/b><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Pure aluminum resistant to corrosion and heat<\/span><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Excellent natural cooling and rapid heat dissipation from internal components on site.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><b style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\"><strong>Mechanical panel-mounting method<\/strong><\/span><\/b><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Integrated lower mounting stud (M12 Stud)<\/span><\/td>\n<td style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px;padding:8px 12px\"><span style=\"font-family:&apos;Google Sans Text&apos;, sans-serif;line-height:1.15;margin-top:0px\">Easy installation and strong mechanical stability inside the capacitor-bank panel base through Gahzly.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3><strong>Engineering and consulting conclusion for the product<\/strong><\/h3>\n<p>When designing and assembling automatic power-factor-correction panels and securing power networks for factories and major commercial projects, while requiring a robust, dependable engineering component that reduces utility penalties and tolerates high harmonics, then<strong>Himel 440 V power-factor correction capacitor<\/strong>represents an efficient and professional engineering recommendation for achieving financial savings and complete network stability, while ensuring supply with approved warranty certificates through your strategic partner, the platform.<strong>Gahzly<\/strong>.<\/p>\n","protected":false},"excerpt":{"rendered":"<h2><strong>Physical operating principle and reactive-power capability of the Himel capacitor (440 V)<\/strong><\/h2>\n<p>The<strong>Himel 440 V power-factor correction capacitor<\/strong>is a key mechanical and electrical component in automatic power-factor-correction panels (APFC Panels) used in factories and commercial complexes. Its physical construction uses self-healing metallized polypropylene film technology. When large inductive loads such as motors and transformers operate, they draw reactive current that reduces the power factor; the Himel capacitor supplies balanced capacitive current to offset that inductive effect immediately on site through the platform.<strong>Gahzly<\/strong>.<\/p>\n<p>The 440 V insulation rating gives the capacitor extended service life and stronger protection against resonance and sudden overvoltage. The Himel capacitor includes a decisive internal overpressure disconnector that safely disconnects the capacitor electrodes automatically if an internal fault occurs, helping prevent explosion inside the panel. It also includes discharge resistors to reduce stored voltage promptly after disconnection, improving technician and engineer safety during routine inspection through the platform.<strong>Gahzly<\/strong>.<\/p>\n","protected":false},"featured_media":137175,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[13184],"product_cat":[15597],"product_tag":[17146,17145],"class_list":["post-125639","product","type-product","status-publish","has-post-thumbnail","product_brand-himel","product_cat--ghz-186","product_tag-capacitors","product_tag-himel","first","instock","sale","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product\/125639","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/comments?post=125639"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media\/137175"}],"wp:attachment":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media?parent=125639"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_brand?post=125639"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_cat?post=125639"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_tag?post=125639"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}