{"id":126946,"date":"2026-08-16T03:19:55","date_gmt":"2026-08-16T00:19:55","guid":{"rendered":"https:\/\/gahzly.com\/?post_type=product&#038;p=126946"},"modified":"2026-08-17T03:57:03","modified_gmt":"2026-08-17T00:57:03","slug":"%d9%86%d9%82%d8%b7%d8%a9-%d9%85%d8%b3%d8%a7%d8%b9%d8%af%d8%a9-%d9%84%d9%84%d9%83%d9%88%d9%86%d8%aa%d8%a7%d9%83%d8%aa%d9%88%d8%b1-%d8%b4%d9%86%d8%a7%d9%8a%d8%af%d8%b1-%d8%a5%d9%84%d9%83%d8%aa%d8%b1","status":"publish","type":"product","link":"https:\/\/gahzly.com\/en\/product\/%d9%86%d9%82%d8%b7%d8%a9-%d9%85%d8%b3%d8%a7%d8%b9%d8%af%d8%a9-%d9%84%d9%84%d9%83%d9%88%d9%86%d8%aa%d8%a7%d9%83%d8%aa%d9%88%d8%b1-%d8%b4%d9%86%d8%a7%d9%8a%d8%af%d8%b1-%d8%a5%d9%84%d9%83%d8%aa%d8%b1\/","title":{"rendered":"Schneider Electric Acti9 iC60 OF Auxiliary Contact"},"content":{"rendered":"<div class=\"container\">\n<div id=\"model-response-message-contentr_7196b3fb82413746\" class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color\" dir=\"rtl\" aria-live=\"polite\">\n<h2 data-path-to-node=\"1\"><strong>OF auxiliary contact for the Schneider Electric iC60 breaker: auxiliary signalling and intelligent distribution-board monitoring<\/strong><\/h2>\n<p data-path-to-node=\"3\"><b data-path-to-node=\"3\" data-index-in-node=\"0\">Transmission of precise digital status signals to monitoring systems<\/b><\/p>\n<ul data-path-to-node=\"4\">\n<li>\n<p data-path-to-node=\"4,0,0\"><b data-path-to-node=\"4,0,0\" data-index-in-node=\"0\">Sending signals through the OF auxiliary contact:<\/b>This architecture allows the<b data-path-to-node=\"4,0,0\" data-index-in-node=\"63\">OF auxiliary contact<\/b>to send clean, low-level status signals to monitoring systems so they can confirm the state of the associated circuit and improve operational visibility on site through<b data-path-to-node=\"4,0,0\" data-index-in-node=\"253\">Gahzly<\/b>.<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"6\"><b data-path-to-node=\"6\" data-index-in-node=\"0\">Easy side mounting and secure attachment to support operational readiness<\/b><\/p>\n<ul data-path-to-node=\"7\">\n<li>\n<p data-path-to-node=\"7,0,0\"><b data-path-to-node=\"7,0,0\" data-index-in-node=\"0\">Secure mounting:<\/b>The<b data-path-to-node=\"7,0,0\" data-index-in-node=\"22\">OF auxiliary contact<\/b>unit is designed for straightforward side installation with secure mechanical attachment, helping it remain stable even in environments subject to vibration on site through<b data-path-to-node=\"7,0,0\" data-index-in-node=\"176\">Gahzly<\/b>.<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"9\"><b data-path-to-node=\"9\" data-index-in-node=\"0\">Operating mechanism and functional interaction of the OF auxiliary contact<\/b><\/p>\n<ul data-path-to-node=\"10\">\n<li>\n<p data-path-to-node=\"10,0,0\"><b data-path-to-node=\"10,0,0\" data-index-in-node=\"0\">The physical principle behind mechanical status transfer:<\/b>The operating principle of<b data-path-to-node=\"10,0,0\" data-index-in-node=\"70\">OF auxiliary contact<\/b>(Open\/Close) is based on converting the physical movement of the miniature circuit breaker handle (iC60 MCB) into a voltage-free electrical signal (Volt-free contacts). When the user raises the breaker handle to the ON position, the internal parts of the<b data-path-to-node=\"10,0,0\" data-index-in-node=\"293\">OF auxiliary contact<\/b>unit move mechanically to change the state of its contacts: the normally open (NO) contact closes and the normally closed (NC) contact opens to signal the control systems within<b data-path-to-node=\"10,0,0\" data-index-in-node=\"467\">Gahzly<\/b>.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"10,1,0\"><b data-path-to-node=\"10,1,0\" data-index-in-node=\"0\">Role of the unit in comprehensive monitoring and control:<\/b>The<b data-path-to-node=\"10,1,0\" data-index-in-node=\"46\">OF auxiliary contact<\/b>unit enables engineers to integrate conventional breakers into smart-building systems or SCADA monitoring panels by providing immediate, reliable feedback on the state of each branch or main breaker within the installation.<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"12\"><b data-path-to-node=\"12\" data-index-in-node=\"0\">Installation engineering and field wiring of the OF auxiliary contact<\/b><\/p>\n<ol start=\"1\" data-path-to-node=\"13\">\n<li>\n<p data-path-to-node=\"13,0,0\"><b data-path-to-node=\"13,0,0\" data-index-in-node=\"0\">Side mounting on the iC60 breaker:<\/b>Installation starts by fully disconnecting the electrical supply, then mounting the<b data-path-to-node=\"13,0,0\" data-index-in-node=\"90\">OF auxiliary contact<\/b>unit on the designated left or right side of the iC60 breaker using the mechanical fastening points designed for quick engagement.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"13,1,0\"><b data-path-to-node=\"13,1,0\" data-index-in-node=\"0\">Connecting signal wires and the control system:<\/b>The auxiliary-contact terminals of the<b data-path-to-node=\"13,1,0\" data-index-in-node=\"68\">OF auxiliary contact<\/b>unit (NO, NC, and Common) are connected to low-current control-signal wiring, with the terminal screws tightened securely on site through<b data-path-to-node=\"13,1,0\" data-index-in-node=\"187\">Gahzly<\/b>.<\/p>\n<\/li>\n<\/ol>\n<p data-path-to-node=\"15\"><b data-path-to-node=\"15\" data-index-in-node=\"0\">Technical specifications and functions table<\/b><\/p>\n<div class=\"horizontal-scroll-wrapper\">\n<div class=\"table-block-component\">\n<div class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\">\n<div class=\"table-content md-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwjwoKG2zs-WAxUAAAAAHQAAAAAQwgI\">\n<table data-path-to-node=\"16\">\n<thead>\n<tr>\n<th><span data-path-to-node=\"16,0,0,0\">Technical specification<\/span><\/th>\n<th><span data-path-to-node=\"16,0,1,0\">Primary function<\/span><\/th>\n<th><span data-path-to-node=\"16,0,2,0\">Practical benefit to the user<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span data-path-to-node=\"16,1,0,0\"><b data-path-to-node=\"16,1,0,0\" data-index-in-node=\"0\">Auxiliary contacts (NO\/NC)<\/b><\/span><\/td>\n<td><span data-path-to-node=\"16,1,1,0\">Electrically reflect the breaker\u2019s ON\/OFF state<\/span><\/td>\n<td><span data-path-to-node=\"16,1,2,0\">Transmit precise signals through<b data-path-to-node=\"16,1,2,0\" data-index-in-node=\"23\">OF auxiliary contact<\/b>to control rooms<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"16,2,0,0\"><b data-path-to-node=\"16,2,0,0\" data-index-in-node=\"0\">Mechanical side-linkage mechanism<\/b><\/span><\/td>\n<td><span data-path-to-node=\"16,2,1,0\">Direct engagement with the iC60 breaker operating mechanism<\/span><\/td>\n<td><span data-path-to-node=\"16,2,2,0\">Immediate, synchronized response to breaker movement<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"16,3,0,0\"><b data-path-to-node=\"16,3,0,0\" data-index-in-node=\"0\">Compact modular design<\/b><\/span><\/td>\n<td><span data-path-to-node=\"16,3,1,0\">Seamless installation beside breakers on DIN rail<\/span><\/td>\n<td><span data-path-to-node=\"16,3,2,0\">Provides<b data-path-to-node=\"16,3,2,0\" data-index-in-node=\"5\">OF auxiliary contact<\/b>an organized use of space inside distribution boards<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"16,4,0,0\"><b data-path-to-node=\"16,4,0,0\" data-index-in-node=\"0\">Precision screw terminals<\/b><\/span><\/td>\n<td><span data-path-to-node=\"16,4,1,0\">Secure connection of control-signal wiring<\/span><\/td>\n<td><span data-path-to-node=\"16,4,2,0\">Helps prevent loose conductors and maintain continuity of status signalling<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"16,5,0,0\"><b data-path-to-node=\"16,5,0,0\" data-index-in-node=\"0\">Full compatibility with the iC60 range<\/b><\/span><\/td>\n<td><span data-path-to-node=\"16,5,1,0\">Engineered integration with Schneider iC60 breakers<\/span><\/td>\n<td><span data-path-to-node=\"16,5,2,0\">Supports reliable, sustained system performance<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"table-footer hide-on-print hide-from-message-actions\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<p data-path-to-node=\"18\"><b data-path-to-node=\"18\" data-index-in-node=\"0\">Objective advantages and limitations<\/b><\/p>\n<ul data-path-to-node=\"19\">\n<li>\n<p data-path-to-node=\"19,0,0\"><b data-path-to-node=\"19,0,0\" data-index-in-node=\"0\">Key advantages:<\/b><\/p>\n<ul data-path-to-node=\"19,0,1\">\n<li>\n<p data-path-to-node=\"19,0,1,0,0\">Immediate and accurate breaker-status feedback provided by<b data-path-to-node=\"19,0,1,0,0\" data-index-in-node=\"48\">OF auxiliary contact<\/b>within the installation.<b data-path-to-node=\"19,0,1,0,0\" data-index-in-node=\"80\">Gahzly<\/b>.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"19,0,1,1,0\">Very easy side installation and secure mechanical engagement with the iC60 breaker.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"19,0,1,2,0\">Flexible signalling through both normally open and normally closed contacts (NO\/NC).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li>\n<p data-path-to-node=\"19,1,0\"><b data-path-to-node=\"19,1,0\" data-index-in-node=\"0\">Limitations and considerations:<\/b><\/p>\n<ul data-path-to-node=\"19,1,1\">\n<li>\n<p data-path-to-node=\"19,1,1,0,0\">The<b data-path-to-node=\"19,1,1,0,0\" data-index-in-node=\"12\">OF auxiliary contact<\/b>unit is intended only for auxiliary signalling and does not itself interrupt power or provide protective tripping.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"19,1,1,1,0\">It requires a small amount of additional space beside the breaker inside the distribution board.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"21\"><b data-path-to-node=\"21\" data-index-in-node=\"0\">Suitable and unsuitable applications<\/b><\/p>\n<ul data-path-to-node=\"22\">\n<li>\n<p data-path-to-node=\"22,0,0\"><b data-path-to-node=\"22,0,0\" data-index-in-node=\"0\">Ideal applications:<\/b><\/p>\n<ul data-path-to-node=\"22,0,1\">\n<li>\n<p data-path-to-node=\"22,0,1,0,0\">Control and monitoring panels in large industrial facilities and commercial buildings using<b data-path-to-node=\"22,0,1,0,0\" data-index-in-node=\"77\">OF auxiliary contact<\/b>through<b data-path-to-node=\"22,0,1,0,0\" data-index-in-node=\"96\">Gahzly<\/b>.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"22,0,1,1,0\">Building Management Systems (BMS) and automation control rooms that require real-time indication of load or breaker status.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li>\n<p data-path-to-node=\"22,1,0\"><b data-path-to-node=\"22,1,0\" data-index-in-node=\"0\">Unsuitable applications:<\/b><\/p>\n<ul data-path-to-node=\"22,1,1\">\n<li>\n<p data-path-to-node=\"22,1,1,0,0\">Use as a substitute for a compatible main protective breaker in high-power circuits.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"22,1,1,1,0\">Installation in environments directly exposed to liquids without a suitably rated IP-protected enclosure.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"24\"><b data-path-to-node=\"24\" data-index-in-node=\"0\">Safe operation and installation method<\/b><\/p>\n<ol start=\"1\" data-path-to-node=\"25\">\n<li>\n<p data-path-to-node=\"25,0,0\"><b data-path-to-node=\"25,0,0\" data-index-in-node=\"0\">Complete Electrical Isolation:<\/b>Disconnect the main supply to the distribution board and measure the voltage to confirm that it is fully de-energized before starting work on site through<b data-path-to-node=\"25,0,0\" data-index-in-node=\"141\">Gahzly<\/b>.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"25,1,0\"><b data-path-to-node=\"25,1,0\" data-index-in-node=\"0\">Mechanical side installation:<\/b>Mount the<b data-path-to-node=\"25,1,0\" data-index-in-node=\"32\">OF auxiliary contact<\/b>unit on the designated side of the iC60 breaker and confirm that the coupling lever engages correctly.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"25,2,0\"><b data-path-to-node=\"25,2,0\" data-index-in-node=\"0\">Electrical signal wiring:<\/b>Connect the monitoring-circuit wires to the auxiliary-contact terminals and tighten the terminal screws securely.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"25,3,0\"><b data-path-to-node=\"25,3,0\" data-index-in-node=\"0\">Field verification test:<\/b>Restore power and operate the breaker handle to verify signal transfer and correct operation of the status indicators through<b data-path-to-node=\"25,3,0\" data-index-in-node=\"112\">OF auxiliary contact<\/b>.<\/p>\n<\/li>\n<\/ol>\n<blockquote data-path-to-node=\"26\">\n<p data-path-to-node=\"26,0\">Important safety notice: Never use the<b data-path-to-node=\"26,0\" data-index-in-node=\"41\">OF auxiliary contact<\/b>unit to carry high-current loads or main power circuits; it is intended exclusively for low-current control and monitoring signals.<\/p>\n<\/blockquote>\n<p data-path-to-node=\"28\"><b data-path-to-node=\"28\" data-index-in-node=\"0\">Maintenance, cleaning, and extending service life<\/b><\/p>\n<ul data-path-to-node=\"29\">\n<li>\n<p data-path-to-node=\"29,0,0\"><b data-path-to-node=\"29,0,0\" data-index-in-node=\"0\">Periodic inspection of connections:<\/b>Regularly inspect the terminal screws of the<b data-path-to-node=\"29,0,0\" data-index-in-node=\"68\">OF auxiliary contact<\/b>unit for any loosening.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"29,1,0\"><b data-path-to-node=\"29,1,0\" data-index-in-node=\"0\">Distribution-board cleanliness:<\/b>Keep the panel free from dust and moisture to protect the unit\u2019s precision mechanical and electrical components.<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"31\"><b data-path-to-node=\"31\" data-index-in-node=\"0\">Important advice before purchase<\/b><\/p>\n<ul data-path-to-node=\"32\">\n<li>\n<p data-path-to-node=\"32,0,0\"><b data-path-to-node=\"32,0,0\" data-index-in-node=\"0\">Checking model compatibility:<\/b>Confirm that your breaker belongs to the iC60 range so that it is fully compatible and mechanically engages correctly with the<b data-path-to-node=\"32,0,0\" data-index-in-node=\"115\">OF auxiliary contact<\/b>unit before purchase through<b data-path-to-node=\"32,0,0\" data-index-in-node=\"145\">Gahzly<\/b>.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"32,1,0\"><b data-path-to-node=\"32,1,0\" data-index-in-node=\"0\">Use Genuine, Traceable Products:<\/b>Source the correct Schneider Electric breaker from<b data-path-to-node=\"32,1,0\" data-index-in-node=\"88\">Gahzly<\/b>to obtain the specified engineering quality, signalling accuracy, and long-term safety performance.<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"34\"><b data-path-to-node=\"34\" data-index-in-node=\"0\">Comprehensive conclusion<\/b><\/p>\n<p data-path-to-node=\"35\">The<b data-path-to-node=\"35\" data-index-in-node=\"5\">OF auxiliary contact<\/b>The OF auxiliary contact for the Schneider Electric iC60 breaker is a practical accessory for improving monitoring and control in modern distribution boards. Its side-mounted mechanical linkage, NO\/NC status signalling, and compact installation provide immediate visibility of breaker state. Selecting the correct genuine accessory and sourcing it through<b data-path-to-node=\"35\" data-index-in-node=\"348\">Gahzly<\/b>is an important step toward improving automated supervision, maintaining reliability, and supporting professional electrical installations.<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2><strong>Comprehensive guide and physical architecture of the Schneider Electric iC60 OF auxiliary contact: engineering auxiliary signalling and intelligent distribution-board monitoring<\/strong><\/h2>\n<p><strong>Introduction to monitoring systems and auxiliary signalling and their roles in electrical networks<\/strong>Modern electrical panels and advanced industrial and commercial systems require precise monitoring methods that allow operators and automation systems to know breaker status instantly without direct visual inspection. The<strong>Schneider Electric iC60 OF auxiliary contact<\/strong>is an engineered accessory designed to transmit the physical state of the breaker, open or closed, to control and alarm circuits through direct integration with the breaker on site through<strong>Gahzly<\/strong>.<\/p>\n<h3>Engineering and physical architecture of the iC60 OF auxiliary contact<\/h3>\n<p><strong>Direct side-mounted mechanical linkage to the breaker\u2019s internal operating mechanism<\/strong>The enclosure uses<strong>Schneider Electric iC60 OF auxiliary contact<\/strong>a rigid molded polymer body with additional internal depth for compatible control components and wiring.<strong>uses a direct side-mounted mechanical linkage to the breaker\u2019s internal operating mechanism<\/strong>within the installation.<strong>Gahzly<\/strong>. This precise mechanical coupling allows the auxiliary contact to follow changes in the main breaker position without intentional delay.<strong>Protruding coupling lever and physical integration with the breaker<\/strong> <strong>The OF auxiliary unit includes a coupling lever that engages directly with the side of the iC60 breaker<\/strong>, acting as a mechanical link that converts movement of the main handle into electrical status signals on site through<strong>Gahzly<\/strong>.<\/p>\n<p><strong>Immediate changeover of the auxiliary NO\/NC contacts<\/strong> <strong>When the breaker handle changes position manually or automatically between ON and OFF, the normally open (NO) and normally closed (NC) auxiliary contacts inside the unit change state accordingly<\/strong>, allowing associated control circuits to change state at the same time on site through<strong>Gahzly<\/strong>.<\/p>\n","protected":false},"featured_media":136424,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[13305],"product_cat":[15924],"product_tag":[],"class_list":["post-126946","product","type-product","status-publish","has-post-thumbnail","product_brand-schneider","product_cat-breaker-auxiliary-contacts","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product\/126946","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/comments?post=126946"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media\/136424"}],"wp:attachment":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media?parent=126946"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_brand?post=126946"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_cat?post=126946"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_tag?post=126946"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}