{"id":127308,"date":"2026-08-16T03:30:18","date_gmt":"2026-08-16T00:30:18","guid":{"rendered":"https:\/\/gahzly.com\/?post_type=product&#038;p=127308"},"modified":"2026-08-17T03:58:17","modified_gmt":"2026-08-17T00:58:17","slug":"schneider-2","status":"publish","type":"product","link":"https:\/\/gahzly.com\/en\/product\/schneider-2\/","title":{"rendered":"schneider"},"content":{"rendered":"<h2><b><strong>Comprehensive guide and physical architecture of the Schneider Electric TeSys thermal overload relay: dual-mode motor protection and operating stability<\/strong><\/b><\/h2>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Automatic interruption of the control circuit when safe operating limits are exceeded<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>These units automatically interrupt the operating circuit when calibrated safe limits are exceeded<\/strong><\/b>within the installation.<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>, by changing the auxiliary-contact state when the bimetal elements deflect from excessive heating, which removes the control signal from the main contactor and stops the motor.<\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Integrated protection to reduce the risk of motor overheating and damage<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>providing integrated protection that helps prevent motor overheating and supports reliable operation<\/strong><\/b>within the installation.<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>, protecting motor windings from sustained excessive current or stalled-rotor conditions.<\/p>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Advanced design features of Schneider Electric TeSys overload relays<\/h3>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Bimetal-strip engineering, ambient-temperature compensation, and current adjustment<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">The TeSys range uses bimetallic strips made from metals with different thermal expansion rates. When current exceeds the calibrated value, the resulting heat bends the strip and operates the mechanical trip mechanism. The relay also uses ambient-temperature compensation to reduce nuisance tripping caused by environmental temperature changes, together with an adjustable overload setting that should be matched to the motor rated current.<\/p>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Operating mechanism and functional interaction of the TeSys overload relay<\/h3>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>The principles behind thermal deflection and control-circuit interruption<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">The overload relay responds to current flowing through the motor circuit. Under normal conditions, current passes through the relay without producing enough heat to reach the trip threshold. During a sustained overload, the bimetal elements heat and deflect until the mechanism changes the auxiliary contacts, typically opening the NC control contact and optionally closing the NO indication contact, causing the contactor to disconnect the motor.<\/p>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Installation and field connection engineering for the TeSys overload relay<\/h3>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Direct mounting below the main contactor<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Installation begins by fully isolating the electrical supply and verifying absence of voltage, then connecting the TeSys overload relay directly below the compatible main contactor and securing the power terminals and mechanical mounting.<\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Connecting the control circuit to the overload relay auxiliary contacts<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">The control circuit, such as the contactor-coil supply path, is wired through the overload relay NC auxiliary contact. The current-setting dial is then adjusted to match the motor nameplate current inside industrial and commercial panels through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Technical specifications and functions table<\/h3>\n<figure class=\"table\">\n<table style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 32px;margin-top: 0px\">\n<thead style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Technical specification<\/strong><\/th>\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Primary function<\/strong><\/th>\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Practical benefit to the user<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Bimetallic protection technology<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Monitoring heat produced by overcurrent using bimetal elements<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Reliable response to motor overheating and protection against sustained overload damage<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Adjustable current-setting dial<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Setting the protection current to match the motor rating accurately<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Flexible matching of the overload relay to different motor current ranges<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Auxiliary contacts (NC \/ NO)<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Opening the control circuit on trip and providing indication or alarm signals<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Automatic motor shutdown and fault or overload indication<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Test and reset controls (Test\/Reset)<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Manual testing of the trip mechanism and resetting the relay after the fault is cleared<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Convenient periodic testing and safe recommissioning after maintenance<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Objective advantages and limitations<\/h3>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>High-accuracy bimetal technology for detecting excessive temperature rise<\/strong><\/b> inside industrial and commercial panels through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Automatic interruption of the operating circuit<\/strong><\/b> when safe motor-protection limits are exceeded through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Integrated protection that helps prevent motor overheating<\/strong><\/b> and supports reliable operating continuity.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Choice of manual or automatic reset<\/strong><\/b> to suit the operating requirements of the application.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Requires accurate current-setting adjustment to match the motor full-load current and avoid nuisance tripping or insufficient overload protection.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Designed for motor overload and phase-related protection; it does not replace an upstream MCCB or MCB for high short-circuit currents.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Suitable and unsuitable applications<\/h3>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Protection of three-phase induction motors against overheating caused by mechanical overload inside industrial and commercial panels through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Protection of water pumps, compressors, and industrial production lines subject to variable operating loads.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Fan and conveyor circuits requiring continuous protection against stalling.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Not suitable for use alone as protection against direct short-circuit faults.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Installation in areas exposed to excessive moisture or dust without a suitable enclosed panel.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Safe operation and installation method<\/h3>\n<ol style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\" start=\"1\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Complete Electrical Isolation:<\/strong><\/b> Fully isolate the electrical supply to the panel and verify absence of voltage inside industrial and commercial panels through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Direct mounting below the contactor:<\/strong><\/b> Connect the TeSys relay terminals below the main contactor and tighten the connections correctly.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Setting the thermal current dial:<\/strong><\/b> Set the adjustment dial to the actual rated operating current of the connected motor.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Connecting control wiring and testing the system:<\/strong><\/b> Wire the auxiliary control contacts into the coil circuit, restore power, and test protection using the Test function inside industrial and commercial panels through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<\/ol>\n<blockquote style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Important safety notice: Incorrect overload-current adjustment can either leave the motor insufficiently protected or cause repeated nuisance trips. Match the setting carefully to the motor rated current.<\/p>\n<\/blockquote>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Maintenance, cleaning, and extending service life<\/h3>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Periodic visual and thermal inspection:<\/strong><\/b> Regularly inspect the overload relay and terminals with thermal imaging for abnormal heating caused by poor connections.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Checking terminal tightness:<\/strong><\/b> Periodically verify terminal screws to account for vibration from motors and machinery.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Internal panel cleanliness:<\/strong><\/b> Keep the panel free from dust and deposits to maintain ventilation and avoid affecting the bimetal mechanism.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Periodic trip-mechanism testing:<\/strong><\/b> Use the Test button periodically to confirm correct operation of the auxiliary trip contacts and control circuit.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Important advice before purchase<\/h3>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Verifying the relay current range against the motor:<\/strong><\/b> Confirm that the TeSys relay current range covers the motor rated current before purchase inside industrial and commercial panels through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Verifying mechanical compatibility with the contactor:<\/strong><\/b> Confirm that the overload-relay model is designed to fit the main contactor series in use before purchase inside industrial and commercial panels through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Use Genuine, Traceable Products:<\/strong><\/b> Source genuine Schneider Electric TeSys products through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b> to ensure verified engineering quality and safe motor protection.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Comprehensive conclusion<\/h3>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">The Schneider Electric TeSys thermal overload relay is an essential protection component for maintaining and extending motor service life in industrial and commercial panels. Its calibrated bimetal technology, ability to detect sustained thermal overload, and automatic control-circuit trip function provide dependable protection against motor overheating. Choosing the original product and sourcing it through <b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b> is a practical step toward improving infrastructure reliability and protecting industrial assets.<\/p>\n","protected":false},"excerpt":{"rendered":"<h2><b><strong>Comprehensive guide and physical architecture of the Schneider Electric TeSys thermal overload relay: dual-mode motor protection and operating stability<\/strong><\/b><\/h2>\n<p><b><strong>Introduction to overload-protection systems and their role in industrial and commercial panels<\/strong><\/b>Reliable motor protection is essential for safe and continuous operation in industrial and commercial facilities, particularly where inductive loads can be damaged by prolonged overcurrent and excessive heating. The Schneider Electric <b><strong>Schneider Electric TeSys Thermal Overload Relay<\/strong><\/b> provides a reliable engineering solution combining bimetal thermal sensing with automatic control-circuit tripping to protect motors through <b><strong>Gahzly<\/strong><\/b>.<\/p>\n<h3>Engineering and physical architecture of the TeSys overload relay<\/h3>\n<p><b><strong>High-accuracy bimetal technology for detecting excessive temperature rise<\/strong><\/b>The enclosure uses<b><strong>Schneider Electric TeSys thermal overload relay<\/strong><\/b>a rigid molded polymer body with additional internal depth for compatible control components and wiring.<b><strong>uses high-accuracy bimetal technology designed to detect excessive temperature rise<\/strong><\/b> caused by overload or stalled operation inside industrial and commercial panels through <b><strong>Gahzly<\/strong><\/b>. The thermal-mechanical design responds directly to heat generated by sustained overcurrent through the relay current paths.<\/p>\n","protected":false},"featured_media":136354,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[13305],"product_cat":[15391],"product_tag":[],"class_list":["post-127308","product","type-product","status-publish","has-post-thumbnail","product_brand-schneider","product_cat-alaofrlod","first","instock","sale","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product\/127308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/comments?post=127308"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media\/136354"}],"wp:attachment":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media?parent=127308"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_brand?post=127308"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_cat?post=127308"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_tag?post=127308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}