{"id":127630,"date":"2026-08-16T03:38:24","date_gmt":"2026-08-16T00:38:24","guid":{"rendered":"https:\/\/gahzly.com\/?post_type=product&#038;p=127630"},"modified":"2026-08-17T03:59:00","modified_gmt":"2026-08-17T00:59:00","slug":"maxge-6","status":"publish","type":"product","link":"https:\/\/gahzly.com\/en\/product\/maxge-6\/","title":{"rendered":"MAXGE"},"content":{"rendered":"<h2><b><strong>Comprehensive guide to Maxge SGM6sm dual-adjustable MCCBs (36kA): advanced thermal and magnetic protection adjustment<\/strong><\/b><\/h2>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>High short-circuit interruption capability (36kA)<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">with<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>With a rated breaking capacity of up to 36kA, the breaker is designed to interrupt short-circuit currents safely within its specified ratings while supporting reliable protection coordination<\/strong><\/b>within the installation.<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>. Its molded enclosure and arc-chute system help contain and dissipate the energy generated during fault interruption, reducing thermal and mechanical stress on the breaker and panel.<\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Operating mechanism and protective response of SGM6sm dual-adjustable breakers<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Thermal and magnetic response principles&amp; Magnetic)<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">The SGM6sm breaker combines two protective functions. The thermal element responds to sustained current above the Ir setting, while the magnetic element responds rapidly to high short-circuit current according to the Ii setting. This combination provides greater flexibility for coordinating protection with loads such as motors that may have high starting currents, while still providing rapid short-circuit protection within the installation through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Installation and field connection of SGM6sm dual-adjustable breakers<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Mechanical mounting inside main and sub-distribution panels<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Begin installation by fully isolating the electrical supply and confirming absence of voltage. Secure the SGM6sm breaker firmly inside the distribution panel using the specified mounting hardware so it remains stable during normal operating vibration at the project or facility through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Connecting terminals and setting the two adjustment dials<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Connect the supply and load cables to the main input and output terminals and tighten the terminals using the specified torque. Then set the thermal adjustment dial (Ir) and magnetic adjustment dial (Ii) according to the approved load and motor calculations for the site through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Technical specifications and functions table<\/strong><\/b><\/p>\n<figure class=\"table\">\n<table style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 32px;margin-top: 0px\">\n<thead style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Technical specification<\/strong><\/th>\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Primary function<\/strong><\/th>\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Practical benefit to the user<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Maximum breaking capacity (36kA)<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Interrupting high short-circuit currents and reducing panel damage<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Protecting the electrical system and supporting safe continuity of service<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Thermal adjustment (Adjustable Ir)<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Setting the overload trip current accurately<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Matching breaker protection to the actual load while reducing nuisance tripping<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Magnetic adjustment (Adjustable Ii)<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Setting the instantaneous short-circuit trip threshold<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Coordinating protection for loads with high starting currents, such as motors, while maintaining rapid fault response<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>High-strength molded enclosure<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Insulating internal components and withstanding mechanical stress<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Supporting breaker service life and safer operation around the distribution panel<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Objective advantages and limitations<\/strong><\/b><\/p>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Advanced protection flexibility<\/strong><\/b>for managing and protecting distribution panels through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Integrated dual thermal and magnetic adjustment<\/strong><\/b>provides control over key protection settings within the specified adjustment ranges.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Rated breaking capacity (36kA)<\/strong><\/b>provides dependable short-circuit protection in suitable applications at the site through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>High flexibility<\/strong><\/b>for coordinating with motor loads that have elevated starting currents while reducing nuisance tripping.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Both Ir and Ii settings require careful adjustment by qualified personnel to avoid incorrect protection settings.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Requires suitable panel space because of the dual-adjustment mechanism and higher-capacity construction.<\/p>\n<\/li>\n<\/ul>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Suitable and unsuitable applications<\/strong><\/b><\/p>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Protecting main and sub-distribution panels in industrial and commercial facilities through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Protecting large industrial motor circuits that require careful coordination with starting currents through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Critical projects that require coordinated operation between multiple protective devices.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Not intended for simple residential circuits that do not require this level of dual adjustment.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Does not provide internet-connected IoT protection functions unless compatible accessories are specifically supported and installed.<\/p>\n<\/li>\n<\/ul>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Safe operation and installation method<\/strong><\/b><\/p>\n<ol style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\" start=\"1\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Complete electrical isolation:<\/strong><\/b>Isolate the main supply and confirm absence of voltage using approved test equipment at the site through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Mechanical mounting:<\/strong><\/b>Mount the breaker securely inside the panel enclosure using the designated hardware.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Electrical connection:<\/strong><\/b>Connect the supply and load cables to the breaker terminals and tighten them using the specified torque to ensure reliable contact.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Dual adjustment:<\/strong><\/b>Set the overload protection dial (Ir) and instantaneous magnetic protection dial (Ii) according to the approved engineering calculations for the installation through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<\/ol>\n<blockquote style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Important safety note: do not adjust Ir or Ii while the circuit is carrying high current. Have the settings reviewed by a qualified electrical engineer to confirm coordination with the connected cables and motors.<\/p>\n<\/blockquote>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Maintenance, cleaning, and extending service life<\/strong><\/b><\/p>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Thermal-imaging inspection:<\/strong><\/b>Use thermal imaging periodically to detect abnormal heating at the connection terminals within the installation through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Periodic tightening of connections:<\/strong><\/b>Review and tighten terminal screws during scheduled maintenance, such as every six months where required by the maintenance plan, to address operating vibration.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Panel cleanliness:<\/strong><\/b>Keep the breaker and surrounding panel area free from dust and deposits to support ventilation and stable operation of internal mechanisms.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Manual operating check:<\/strong><\/b>During scheduled maintenance, operate the breaker handle manually between ON and OFF positions, where permitted, to confirm smooth mechanical operation.<\/p>\n<\/li>\n<\/ul>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Important advice before purchase<\/strong><\/b><\/p>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Study the load characteristics accurately:<\/strong><\/b>Calculate continuous operating currents and motor starting currents before determining the appropriate Ir and Ii settings for the project through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Verify the breaking capacity:<\/strong><\/b>Before purchase, confirm that the 36kA breaking capacity is suitable for the prospective short-circuit current calculated for the installation through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Purchase from an approved source:<\/strong><\/b>Source genuine Maxge SGM6sm breakers through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>to help ensure verified engineering quality and dependable protection.<\/p>\n<\/li>\n<\/ul>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Comprehensive conclusion<\/strong><\/b><\/p>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">The Maxge SGM6sm dual-adjustable MCCB family with a 36kA breaking capacity provides flexible protection for main and sub-distribution panels in industrial, commercial, and critical-project applications. Its combined adjustable thermal&amp;Magnetic Unit allows qualified engineers to coordinate the Ir and Ii trip settings with actual load and motor characteristics, while the 36kA breaking capacity provides short-circuit interruption within the breaker rating. Choosing the genuine product and sourcing it through<b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Gahzly<\/strong><\/b>is an important step toward improving protection coordination, operational stability, and electrical-system safety.<\/p>\n","protected":false},"excerpt":{"rendered":"<h2><b><strong>Comprehensive guide to Maxge SGM6sm dual-adjustable MCCBs (36kA): advanced thermal and magnetic protection adjustment<\/strong><\/b><\/h2>\n<p><b><strong>Introduction to SGM6sm dual-adjustable molded-case circuit breakers and their engineering role<\/strong><\/b>Modern power-distribution systems often require precise coordination between connected loads and protective devices. In this context, the<b><strong>Maxge SGM6sm Fully Adjustable MCCB family<\/strong><\/b> provides <b><strong>provides advanced and flexible protection for main and sub-distribution panels in industrial, commercial, and critical-project applications<\/strong><\/b>, available through <b><strong>Gahzly<\/strong><\/b>. This family allows qualified electrical engineers to adjust both overload and instantaneous protection settings, supporting improved coordination under different load conditions.<b><strong>Engineering, physical, and operating architecture of Maxge SGM6sm dual-adjustable MCCBs (36kA)<\/strong><\/b><\/p>\n<p><b><strong>Integrated dual-adjustment system (Adjustable Thermal&amp; Magnetic Unit)<\/strong><\/b>This model features<b><strong>combined adjustable thermal and magnetic protection (Adjustable Thermal&amp;Magnetic Unit), allowing qualified engineers to set the overload trip threshold (Thermal Trip Setting &#8211; Ir) and the instantaneous short-circuit trip threshold (Magnetic Trip Setting &#8211; Ii) within the manufacturer-specified ranges to suit the operating characteristics of the connected loads and larger motors<\/strong><\/b>within the installation.<b><strong>Gahzly<\/strong><\/b>. This dual adjustment allows the continuous-current protection and instantaneous fault response to be coordinated more precisely, helping reduce unwanted interaction between protective devices in series.<\/p>\n","protected":false},"featured_media":136310,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[12796],"product_cat":[15381],"product_tag":[12355,16721],"class_list":["post-127630","product","type-product","status-publish","has-post-thumbnail","product_brand---en","product_cat-alkoataa-almsbob","product_tag-maxge-en","product_tag-moulded-case-circuit-breakers-mccb","pa_ampere-160a-en","first","instock","sale","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product\/127630","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/comments?post=127630"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media\/136310"}],"wp:attachment":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media?parent=127630"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_brand?post=127630"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_cat?post=127630"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_tag?post=127630"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}