{"id":127839,"date":"2026-08-16T03:44:25","date_gmt":"2026-08-16T00:44:25","guid":{"rendered":"https:\/\/gahzly.com\/?post_type=product&#038;p=127839"},"modified":"2026-08-17T03:59:39","modified_gmt":"2026-08-17T00:59:39","slug":"schneider-4","status":"publish","type":"product","link":"https:\/\/gahzly.com\/en\/product\/schneider-4\/","title":{"rendered":"Schneider"},"content":{"rendered":"<h2>Comprehensive guide to Schneider contactor coils: electrical architecture, magnetic-generation mechanisms, and control engineering<\/h2>\n<h4 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Compatibility with AC and DC voltages<\/h4>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">These coils are engineered for industrial control networks and are available for multiple operating voltages, including alternating current (AC) and direct current (DC). This allows engineers to select the correct coil for circuits operating at 24 V, 110 V, 220\/380 V, or other specified control voltages and facilitates integration with PLC systems and control power supplies.<\/p>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Magnetic-generation mechanisms and mechanical pull-in process<\/h3>\n<h4 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Converting electrical energy into mechanical motion<\/h4>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">When the specified operating voltage is applied to the coil terminals, current flows through the winding and creates magnetic flux according to electromagnetic principles. This magnetic flux attracts the moving part of the iron core toward the fixed part, producing rapid mechanical motion that closes the main contacts and connects power to the industrial load.<\/p>\n<h4 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Preventing vibration and magnetic resonance<\/h4>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">In AC coils, Schneider uses shading coils (Shading Coils) on the magnetic core to reduce vibration and humming associated with alternating-current frequency. This helps keep the core stable while energized continuously and reduces mechanical wear.<\/p>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Technical specifications and functions table<\/h3>\n<figure class=\"table\">\n<table style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 32px;margin-top: 0px\">\n<thead style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Technical specification<\/strong><\/th>\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Primary function<\/strong><\/th>\n<th style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><strong style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-bottom: 0px;margin-top: 0px\">Practical benefit to the user<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>High-purity copper wires with double insulation<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Safe current conduction and magnetic-field generation.<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Long service life and strong resistance to thermal rise.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Compatibility with AC and DC voltages<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Operation from different control power sources.<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">High flexibility when connecting the contactor to available control circuits.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Precisely designed magnetic iron core<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Concentrates magnetic flux lines to improve pull-in efficiency.<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Fast response and reduced coil power consumption.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>Shading coils for AC coils<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Reduce vibration and resonance during continuous energization.<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Quiet, stable operation that helps protect adjacent mechanical components.<\/span><\/td>\n<\/tr>\n<tr style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><b style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\"><strong>High-grade thermal insulation (Class F\/H)<\/strong><\/span><\/b><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Protects the coil from overheating under demanding operating conditions.<\/span><\/td>\n<td style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px;padding: 8px 12px\"><span style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Supports reliability and safety in heavy industrial environments.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Objective advantages and limitations<\/h3>\n<h4 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Key advantages:<\/h4>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">High energy efficiency: reduces thermal losses inside enclosed control panels.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Multiple operating voltages: available in various AC and DC voltage ratings to suit different designs.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">High operating reliability: designed for a large number of switching cycles when used within its ratings.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Easy replacement: some series allow a damaged coil to be replaced without replacing the entire contactor.<\/p>\n<\/li>\n<\/ul>\n<h4 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Disadvantages and limitations:<\/h4>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Sensitivity to voltage variation: voltage above or below the coil rating can cause overheating, coil damage, or incomplete pull-in.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Effect of ambient temperature: very high temperatures inside uncooled panels can shorten the life of the coil insulation.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Suitable and unsuitable applications<\/h3>\n<h4 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Ideal applications:<\/h4>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Operating main contactors in automated control panels and motor control centers (MCC).<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Applications requiring frequent and rapid switching of industrial and commercial loads.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Automation systems requiring accurate matching between PLC output voltage and operating coils.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Critical industrial lines requiring high reliability and continuity of operation.<\/p>\n<\/li>\n<\/ul>\n<h4 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Unsuitable applications:<\/h4>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Operating the coil at a voltage different from its marked rating, such as connecting a 110 V coil to 220 V.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Use in very humid or chemically corrosive environments without suitable external protection.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Safe operation and installation method<\/h3>\n<ol style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\" start=\"1\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Complete electrical isolation: isolate the control panel and disconnect all power sources before inspecting or replacing the coil.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Checking coil voltage: verify that the new coil voltage exactly matches the available control-circuit voltage.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Removing and installing the coil: carefully remove the contactor cover, replace the damaged coil with the correct original part, and make sure it is seated securely around the magnetic core.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Connecting wire terminals: tighten the control-circuit wires securely to coil terminals (A1 and A2) to prevent loose connections and arcing.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Final engineering check: restore power and test contactor response and magnetic pull-in operation.<\/p>\n<\/li>\n<\/ol>\n<blockquote style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Important safety warning: applying a voltage above the coil rating can quickly overheat and damage the coil, while insufficient voltage may prevent complete pull-in and cause dangerous heating.<\/p>\n<\/blockquote>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Maintenance, cleaning, and extending service life<\/h3>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Periodic voltage check: verify that the control-circuit voltage remains stable and free from abnormal dips or surges.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Regular dry cleaning: remove dust and debris around the magnetic core using clean, dry compressed air.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Operating-temperature monitoring: check for abnormal heating caused by incomplete closure of the contactor magnetic core.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Important advice before purchase<\/h3>\n<ul style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Identify the coil voltage accurately: confirm whether the available control supply is AC or DC and its voltage value before ordering.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Choose genuine parts: use original coils to ensure mechanical and electrical compatibility with the contactor and dependable support.<\/p>\n<\/li>\n<li style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Review current consumption: make sure the control power source can supply the coil&#8217;s inrush current (Inrush Current) for reliable operation.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"font-family: &#039;Google Sans&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">Comprehensive conclusion<\/h3>\n<p style=\"font-family: &#039;Google Sans Text&#039;, sans-serif;line-height: 1.15;margin-top: 0px\">The Schneider contactor coil is a fundamental component of an automated control system, converting electrical control signals into magnetic force that operates the contacts. Its engineered magnetic circuit, insulated copper windings, and range of operating voltages support stable performance in industrial panels. Correct coil selection, genuine parts, and proper maintenance help improve system reliability and safety over the long term.<\/p>\n","protected":false},"excerpt":{"rendered":"<h2>Comprehensive guide to Schneider contactor coils: electrical architecture, magnetic-generation mechanisms, and control engineering<\/h2>\n<h3>Introduction to contactor coil systems<\/h3>\n<p>In electrical-panel engineering and automation, safely controlling high-power circuits through low-voltage control signals is essential for personnel safety and equipment stability. The contactor coil, also referred to as the electromagnet, converts electrical energy into the magnetic force needed to pull in the main contacts and energize industrial loads. Schneider Electric coils are designed for different AC and DC control voltages, with attention to energy efficiency and limiting heat losses inside control panels.<\/p>\n<h3>Electrical and physical architecture of Schneider contactor coils<\/h3>\n<h4>Engineering design of windings and high-purity copper<\/h4>\n<p>Schneider contactor coils use high-purity copper windings with insulation designed to withstand elevated temperatures and the electrical stress of frequent switching. The winding is formed around a magnetic iron core designed to reduce eddy-current and thermal losses, supporting a strong and stable magnetic field when energized.<\/p>\n<h4>Compatibility with AC and DC voltages<\/h4>\n<p>These coils are engineered for industrial control networks and are available for multiple operating voltages, including alternating current (AC) and direct current (DC). This allows engineers to select the correct coil for circuits operating at 24 V, 110 V, 220\/380 V, or other specified control voltages and facilitates integration with PLC systems and control power supplies.<\/p>\n","protected":false},"featured_media":136270,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[13305],"product_cat":[15964],"product_tag":[],"class_list":["post-127839","product","type-product","status-publish","has-post-thumbnail","product_brand-schneider","product_cat-contactor-coils","first","instock","sale","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product\/127839","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/comments?post=127839"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media\/136270"}],"wp:attachment":[{"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/media?parent=127839"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_brand?post=127839"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_cat?post=127839"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gahzly.com\/en\/wp-json\/wp\/v2\/product_tag?post=127839"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}