SALE
In stockSKU: GHZ-91X-18-804

Maxge

Price range: 3.300,00 EGP through 9.800,00 EGP

Comprehensive Guide and Electrical/Physical Architecture of the Maxge Under-Voltage Release 220 VAC: Automatic Protection Against Undervoltage Conditions

Introduction to the Maxge Under-Voltage Release – UVR 220 VAC and its engineering roleIn electrical power systems affected by voltage fluctuations and sudden disturbances, motors and sensitive equipment may require automatic protection against sustained undervoltage. The Under-Voltage Release – UVR 220 VAC from Maxgeprovidesis a critical electromechanical protection and tripping accessory intended for compatible large circuit breakers and molded-case circuit breakers (MCCB), available throughGahzly. This accessory helps provide automatic breaker tripping when the monitored supply falls below the operating range, supporting protection of electrical equipment against damaging undervoltage conditions.Electrical, physical, and operating architecture of the Maxge undervoltage release

Continuous voltage monitoring and automatic-trip mechanism The undervoltage release operates by maintaining a magnetic field that holds the mechanical trip mechanism in the normal operating state. The coil continuously monitors the supply voltage at its nominal operating voltage of 220 V AC (220V AC). While the voltage remains within the acceptable operating range, the magnetic core holds the release mechanism in position. If the voltage falls below the permitted threshold or is lost, typically within a manufacturer-defined range that may be around 35% to 70% of nominal voltage, the coil releases the mechanism and automatically trips the circuit breaker, preventing continued operation under severe undervoltage conditions at the site through Gahzly.

SKU: GHZ-91X-18-804 Category:
Trusted products
Secure payment
Technical support
Reliable shipping
Your order is protected and can be reviewed before payment.
Verified product data

Technical specifications

A single structured view of reviewed Product Entry data and canonical WooCommerce specifications.

Size
MGW6-1600، MGW6-2000، MGW6-3200، MGW6-4000، MGW6-7500

Description

Comprehensive Guide and Electrical/Physical Architecture of the Maxge Under-Voltage Release 220 VAC: Automatic Protection Against Undervoltage Conditions

Protecting motors and sensitive equipment against undervoltage

The primary purpose of this accessory is to protect motors and sensitive electronic loads against undervoltage conditions that can cause abnormal current, stalled operation, or unsafe restarting behavior when voltage returns. This helps protect motors and sensitive equipment against undervoltage-related damage at the site through the Gahzly platform and supports a stable operating environment when correctly selected and installed.

Field installation and connection of the Maxge undervoltage release

Internal installation within the breaker’s mechanical structure

Begin installation by disconnecting all electrical supplies from the main breaker, whether an MCCB or air circuit breaker, and verifying the absence of voltage. Install the undervoltage release carefully in the breaker’s designated accessory cavity and make sure the mechanical mounting points match the manufacturer’s instructions at the site through Gahzly.

Connecting the 220 V AC monitoring circuit

Connect the (UVR) coil terminals to the 220 V AC supply/monitoring circuit according to the approved wiring diagram. Tighten the terminals carefully to maintain a stable signal and avoid momentary interruptions that could cause nuisance tripping at the installation through Gahzly.

Technical specifications and functions table

Technical specificationPrimary functionPractical benefit to the user
Nominal operating voltage (220V AC)Continuous monitoring of the AC supply voltageEngineered compatibility with standard control networks
Automatic trip threshold (35%-70%)Detecting severe undervoltage and issuing an immediate trip commandHelping prevent motor and sensitive-equipment damage caused by undervoltage
Spring-opposed electromagnetic holding mechanismMaintaining the connected state while adequate voltage is present and releasing when voltage is lostProviding autonomous mechanical protection without dependence on software systems
Compatibility with MCCB and ACB circuit breakersStraightforward internal installation in compatible large Maxge breakersAdding advanced protective functionality to compatible standard breakers

Objective advantages and limitations

  • Critical electromechanical protection and tripping unit for large and molded-case circuit breakers through Gahzly.

  • Continuous and immediate monitoring of the supply voltage with fast response when voltage falls below the safe threshold.

  • Effective protection for motors and sensitive equipment against undervoltage conditions and abnormal restarting current through Gahzly.

  • High reliability in automatic mechanical tripping without requiring human intervention or complex external signals.

  • Requires reasonably stable network voltage to reduce nuisance trips caused by brief transient dips.

  • Requires careful selection and skilled installation when mounting internally and wiring the control circuit.

Suitable and unsuitable applications

  • Protecting large industrial motor feeders that are adversely affected by undervoltage through Gahzly.

  • Protecting main and sub-distribution boards that supply electronic and sensitive loads through Gahzly.

  • Power systems in factories and high-rise buildings that require immediate safe tripping during severe undervoltage through Gahzly.

  • Not suitable for electrical networks with continuous unstable voltage fluctuation where repeated nuisance tripping would occur.

  • Not suitable for simple electrical panels and circuits that do not require dedicated undervoltage protection.

Safe operation and installation method

  1. Complete electrical isolation: Disconnect the main supply from the breaker and verify the absence of voltage with measuring instruments before starting work at the site through Gahzly.

  2. Mechanical mounting: Place the undervoltage release in its designated cavity inside the breaker and secure it with the approved fasteners to ensure stable mounting.

  3. Electrical connection: Connect the 220 V AC monitoring wires to the designated coil terminals and tighten them carefully.

  4. Inspection and commissioning test: Perform a controlled voltage-reduction test to confirm that the release trips the breaker at the specified threshold at the installation through Gahzly.

Important safety warning: never force the breaker to remain in the (ON) position while undervoltage or loss of supply persists at the (UVR) coil, because the release is designed to prevent breaker closing until the monitored voltage returns to a safe operating level.

Maintenance, cleaning, and extending service life

  • Periodic inspection of electrical connections: Check that the monitoring-wire terminal screws remain tight to prevent contact resistance or signal interruption at the site through Gahzly.

  • Internal mechanical cleanliness: Keep the area around the release free from dust and deposits so the plunger and electromechanical parts can move freely.

  • Periodic performance test: Test release operation by simulating a controlled undervoltage condition to confirm accurate breaker tripping.

  • Monitor network-voltage stability: Check for severe or continuous fluctuations in the monitored supply voltage (220V AC) to reduce unnecessary operating stress on the coil.

Important advice before purchase

  • Confirm model compatibility: Verify that the undervoltage release is fully compatible with the type and model of your circuit breaker, such as a compatible Maxge MCCB or ACB, before purchasing at the site through Gahzly.

  • Selecting the operating voltage accurately: Confirm that the monitoring supply is exactly 220 V AC before selecting the release for the installation through Gahzly.

  • Use Genuine, Traceable Products:Source genuine Maxge accessories throughGahzly to support product quality, correct calibration, and engineered safety.

Comprehensive conclusion

The Maxge Under-Voltage Release – UVR 220 VAC is a critical electromechanical protection accessory for compatible large and molded-case circuit breakers. By continuously monitoring the supply voltage and mechanically tripping the breaker when voltage falls below the permitted operating threshold, the release helps protect motors and sensitive equipment and supports network stability. Selecting the correct genuine accessory and sourcing it through Gahzly is an important step toward strengthening preventive protection, reducing costly failures, and maintaining a safer and more stable operating environment.

Reviews

There are no reviews yet.


Show only reviews in English (0)

Be the first to review “Maxge”

Technical discussion

Product Questions & Answers

0

No questions yet. Ask the supplier about specifications, compatibility, certifications or installation requirements.

Sign in to ask

Gahzly Panel Designer

Use this product in the Electrical Panel Builder

Carry this catalog product into a new panel design. Qualified component-family rules and exact-variation checks remain enforced inside the builder.

Open in Panel Builder