Schneider
Price range: 20.777,90 EGP through 21.613,10 EGP
Comprehensive guide to Schneider circuit-breaker tripping coils (Shunt / UVR): remote safety control and emergency disconnection in electrical panels
Introduction to tripping and release coils in circuit breakersModern electrical protection systems may require remote circuit-breaker opening in addition to automatic overcurrent protection. Circuit Breaker Tripping Coils&and Releases such as the Shunt Trip – MX and Undervoltage Release – MN from Schneider Electric provide auxiliary tripping functions for emergency-stop systems, fire-alarm interfaces, undervoltage protection, and remote control. Depending on the breaker family, these releases can be fitted to devices such as iC60/iC120 miniature breakers, Compact NSX molded-case breakers, and Masterpact air circuit breakers.Electrical and physical architecture of Schneider circuit-breaker releases (Shunt / UVR)
Electromagnetic design of the external shunt-trip release (Shunt Trip – MX)The MX Shunt Trip uses an electromagnetic coil designed to receive an external electrical command, available in specified DC or AC control-voltage versions. A signal from an emergency circuit, Emergency Pushbuttons, or a fire-alarm system energizes the coil and actuates the breaker’s Tripping Mechanism, opening the main contacts rapidly.
Please sign in to submit a product report.
- Description
- Reviews
Description
Comprehensive guide to Schneider circuit-breaker tripping releases (Shunt / UVR): remote safety control and emergency disconnection in electrical panels
Continuous-voltage sensing of the undervoltage release (Undervoltage Release – MN)
In contrast, theSchneider circuit-breaker release(type MN UVR) is energized continuously while the supply voltage remains within its specified operating range. The energized release permits the breaker mechanism to remain closed; when voltage falls below the release threshold or is lost, the mechanism trips or prevents closing according to the device design. Typical operating thresholds may be specified around 70% to 110% of rated voltage, depending on the exact product documentation.Gahzly.
Mechanical integration inside industrial and miniature circuit breakers
These releasesSchneider circuit-breaker releaseuse a compact form designed to fit designated auxiliary locations in compatible Schneider breaker families such as iC60, iC120, Compact NSX, and Masterpact. Electrical terminals and mechanical actuating features interface with the breaker’s internal operating mechanism.Gahzly.
Operating mechanism and functional interaction of Shunt& UVR)
Immediate response of the shunt-trip release (MX) in emergency conditionsThe operating mechanism of aSchneider circuit-breaker releaseThe MX Shunt Trip function responds to an external control command. When an emergency-stop circuit or fire-alarm system energizes the release, its electromagnetic actuator operates the breaker trip mechanism and disconnects the designated circuit.Gahzly.
Undervoltage Release – MN protection against inadequate supply voltageThe operating mechanism of theSchneider circuit-breaker releaseUVR release continuously depends on the control voltage and can prevent the breaker from remaining closed or being reclosed while the voltage is below the permitted threshold, helping protect motors and sensitive equipment from operation under inadequate voltage.Gahzly.
Field installation and wiring of tripping releases
Internal mounting without complex toolsShunt or UVR releasesSchneider circuit-breaker releaseare installed in designated Auxiliary Slots within compatible breaker bodies. Their mechanical actuator must engage correctly with the breaker’s internal trip mechanism.Gahzly.
Electrical connection of control and monitoring circuitsControl wiring for theSchneider circuit-breaker releaserelease is connected to the designated screw or quick-connect terminals and routed to the external emergency, monitoring, or control circuit. The release voltage rating must match the control-system voltage.Gahzly.
Technical specifications and functions table
Objective advantages and limitations
Key advantages:
Provides remote circuit-opening capability for emergency and safety systemsSchneider circuit-breaker releasewithin the installation.Gahzly.
Provides effective undervoltage-related protection for motors and sensitive equipment when the correct MN release is used.
Engineered compatibility with designated Schneider circuit-breaker familiesSchneider circuit-breaker release.
Fast response to electrical trip commands.
Objective disadvantages and limitations:
requires handling Schneider circuit-breaker release very high accuracy in matching the coil voltage to the control-circuit voltage to avoid coil damage from continuous energization.
A slight increase in the wiring complexity of control circuits inside the electrical panel.
Suitable and unsuitable applications
Ideal applications:
Connecting electrical panels to centralized fire-alarm and firefighting systems for emergency tripping using Schneider circuit-breaker releasewithin the installation.Gahzly.
Protecting feeder lines for large motors and sensitive industrial equipment against sudden undervoltage.
Hospitals, shopping centers, and factories that require strict safety protocols for emergency power disconnection through Schneider circuit-breaker release.
Unsuitable applications:
Simple residential panels that do not require alarm systems or remote emergency control and do not contain breakers that support Schneider circuit-breaker release.
Using coils with voltages incompatible with the available control-circuit voltage on site.
Safe operation and installation method
Complete electrical isolation: disconnect power from the electrical panel completely and verify the absence of voltage with approved measuring instruments before beginning installation of Schneider circuit-breaker releasewithin the installation.Gahzly.
Installing the coil in the breaker: gently push the release coil into the designated side cavity of the breaker until it is fully seated.
Control-wiring connection: connect the emergency-signal wires or control voltage to the terminals of Schneider circuit-breaker release with engineering precision at the site through Gahzly.
Testing and verification: restore power to the panel and test the coil by sending an emergency trip pulse or reducing the voltage to confirm that the breaker opens immediately.
Important safety warning: never touch the connection terminals of Schneider circuit-breaker release or attempt installation while the electrical system is energized, to avoid electric shock or sudden coil damage.
Maintenance, cleaning, and extending service life
Periodic inspection of control connections: regularly verify the security of the wires of Schneider circuit-breaker release and ensure they are free from corrosion or moisture at the site through Gahzly.
Response-efficiency test: perform scheduled periodic emergency-trip tests to confirm proper coil operation and breaker response.
Cleanliness around the breaker interior: ensure that the panel and the installation area of Schneider circuit-breaker release are free from dust and contaminants that could obstruct mechanical movement.
Important advice before purchase
Accurately identify the coil type: choose the appropriate coil for your requirement when purchasing Schneider circuit-breaker release; whether (MX) for pulse-operated emergency tripping, or (MN) for continuous undervoltage protection at the site through Gahzly.
Operating-voltage matching: make sure the control-coil voltage exactly matches your control-system voltage, whether 24 V, 220 V, or another value.
Buy from approved sources: choose genuine Schneider Electric products and compatible accessoriesSchneider circuit-breaker releasefrom authorized channelsGahzly to ensure quality, full compatibility with your breakers, and access to approved support.
Comprehensive conclusion
TheSchneider circuit-breaker release (Shunt / UVR) is a key actuating element for establishing high safety standards and emergency protection in industrial and commercial electrical panels. With precise response to emergency pulses or voltage-stability monitoring, these releases help provide integrated protection for people, property, and sensitive equipment. Selecting genuine accessories and sourcing them through Gahzly is a sound strategic step toward ensuring the reliability and safety of your electrical system under varying operating conditions.
Be the first to review “Schneider”
You must be logged in to post a review.
Product Questions & Answers
No questions yet. Ask the supplier about specifications, compatibility, certifications or installation requirements.
Recently viewed products
Use this product in the Electrical Panel Builder
Carry this catalog product into a new panel design. Qualified component-family rules and exact-variation checks remain enforced inside the builder.






Reviews
There are no reviews yet.